Description
This versatile 12V 100Ah lithium ion phosphate battery is one of our most popular batteries. The RB100 is a safer, more lightweight alternative to lead-acid in your marine, solar, RV or other applications. It maintains consistent power and is equipped with an M8 terminal type and a built-in battery management system (BMS). The RB100 battery meets UL, UN, CE and IEC certifications.
All RELiON LiFePO4 batteries have installation flexibility, fast-charging capabilities and are maintenance free, Where maintaining water is never done because there is no water in these batteries, and the life expectancy is 10 to 12 years. They can be run clear down tell they stop. and recharge, or can be recharged any time you finish using them, there is no memory to worry about like lead acid batteries.
PRODUCT SPECIFICATIONS
Voltage: 12.8V
Amp Hours: 100Ah
DIMENSIONS & WEIGHT
Length: 13 in (329 mm)
Width: 6.8 in (172 mm)
Height: 8.8 in (223 mm)
Weight: 29.8 lbs (13.5 kg)
APPLICATIONS
AWP
Electric Vehicles
Floor Machines
Marine
Recreational Vehicles
Solar
ELECTRICAL SPECIFICATIONS |
Nominal Voltage |
12.8 V |
Nominal Capacity |
100 Ah |
Capacity @ 25A |
240 min |
Energy |
1280 Wh |
Resistance |
30 mΩ @ 50% SOC |
Efficiency |
99% |
Self Discharge |
3% per Month |
Maximum Modules in Series |
6 |
MECHANICAL SPECIFICATIONS |
Dimensions (L x W x H) |
13.0 x 6.8 x 8.8” (329 x 172 x 223 mm) |
Weight |
30 lbs (13.5 kg) |
Terminal Type |
M8 |
Terminal Torque |
80 - 100 in-lbs (9 - 11 N-m) |
Case Material |
ABS |
Enclosure Protection |
IP56 |
Cell Type - Chemistry |
Cylindrical - LiFePO4 |
DISCHARGE SPECIFICATIONS |
Maximum Continuous Discharge Current |
100 A |
Peak Discharge Current |
200 A (7.5 s ±2.5 s) |
BMS Discharge Current Cut-Off |
280 A ±50 A (9 ±4 ms) |
Recommended Low Voltage Disconnect |
11 V |
BMS Discharge Voltage Cut-Off |
8 V (2.0 ±0.08 vpc) (140 ±60 ms) |
Reconnect Voltage |
9.2 V (2.3 ±0.1 vpc) |
Short Circuit Protection |
200-600 µs |
CHARGE SPECIFICATIONS |
Recommended Charge Current |
5 A - 50 A |
Maximum Charge Current |
100 A |
Charge Current 32°F to 14°F (0 to -10°C) |
≤0.1 C |
Charge Current 14°F to -4°F (-10 to -20°C) |
≤0.05 C |
Recommended Charge Voltage |
14.2 V - 14.6 V |
BMS Charge Voltage Cut-Off |
15.6 V (3.9 ±0.025 vpc) (1.1 ±0.4 s) |
Reconnect Voltage |
15.2 V (3.8 ±0.05 vpc) |
Balancing Voltage |
14.4 V (3.6 ±0.025 vpc) |
TEMPERATURE SPECIFICATIONS |
Discharge Temperature |
-4 to 140 ºF (-20 to 60 ºC) |
Charge Temperature* |
-4 to 113 ºF (-20 to 45 ºC) |
Storage Temperature |
23 to 95 ºF (-5 to 35 ºC) |
BMS High Temperature Cut-Off |
176 ºF (80 ºC) |
Reconnect Temperature |
122 ºF (50 ºC) |
*Refer to charge currents below 32°F (0°C) |
|
COMPLIANCE SPECIFICATIONS |
Certifications |
CE (battery) |
|
UN38.3 (battery) |
|
UL1642 & IEC62133 (cells) |
Shipping Classification |
UN 3480, CLASS 9 |